EMBRITAL refrigeration products

 

Embraco

 

EG foto emfoto F foto
EM F EG

 

 

 

DOWNLOAD EMBRACO'S CATALOGUE

 

SERIE EM R134a-R513A

Model Power Source [V/Hz] Displacement [cc/rev] Capacity / Evaporating Temperature - ASHRAE Motor
type
Check Point -23.3°C Check Point +7.2°C -30°C -25°C -20°C -15°C -10°c -5°C 0°C +5°C +10°C +15°C
CAP [W] COP [W/W] CAP [W] COP [W/W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W]
EM 30HHR
50-60Hz
220-240/50 3.00 76 0.88 343 2.45 49 71 96 127 164 206 256 312 377 450 RSIR/CSIR
 230/60 91 1.01 404 2.53 57 85 117 153 196 246 306 376 458 554
EM 30HHR 115/60 3.00 91 0.94 407 2.50 58 85 116 154 197 249 309 379 460 553 RSIR
EM 45HHR 220-240/50 3.77 102 1.03 440 2.63 61 85 116 154 200 255 320 396 484 585 RSIR/CSIR
EMI 45HER 115-127/60 3.77 123 1.26 - - 74 109 150 196 248 - - - - - RSIR
EM 55HHR
50-60Hz
220-240/50  4.60 - - 533 2.69 - - - - - 326 399 485 583 694 RSIR
230/60 - - 630 2.60 - - - - - 377 471 579 701 837
EM 55HHR 115-127/60 4.60 - - 630 2.52 - - - - - 365 454 560 681 819 RSIR
EM 65HHR 220-240/50 5.54 - - 639 2.61 - - - - - 405 475 567 681 818 RSIR
EM 65HHR
50-60Hz
220-240/50 5.54 - - 645 2.39 - - - - 304 388 484 592 711 842 RSIR/CSIR
230/60 - - 766 2.49 - - - - 381 473 581 705 845 1,001
EM 65HHR 115/60 5.54 - - 762 2.50 - - - - 358 447 554 680 824 986 RSIR

 

 Rated Test Conditions:

Condensing Temperature 54.4°C
Liquid Temperature 32.2°C
Suction Temperature 32.2°C
Ambient Temperature 32.2°C

 

 

 

SERIE EG/F R134a-R513A

Model Power Source [V/Hz] Displacement [cc/rev] Capacity / Evaporating Temperature - ASHRAE Motor
type
Check Point -23.3°C Check Point +7.2°C -30°C -25°C -20°C -15°C -10°c -5°C 0°C +5°C +10°C +15°C
CAP [W] COP [W/W] CAP [W] COP [W/W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W]
EGAS 80HLR 115-127/60 6.36 240 1.55 - - 151 215 289 377 482 - - - - - RSIR/CSIR
EGAS 90HLR
50/60Hz
220-240/50 7.15 219 1.50 - - 143 197 260 335 424 - - - - - RSIR/CSIR
230/60 271 1.59 - - 175 243 320 413 524 - - - - -
EGAS 90HLR 115-127/60 7.15 275 1.59 - - 175 243 320 413 524 - - - - - RSIR/CSIR
EGAS 100HLR
50-60Hz
220-240/50 7.95 251 1.52 - - 162 225 298 383 483 - - - - - RSIR
230/60 308 1.60 - - 200 277 366 470 593 - - - - -
EGAS 100HLR 115-127/60 7.95 308 1.58 - - 200 277 366 470 593 - - - - - RSIR/CSIR
FFI 8.5HAK
50-60Hz
220-240/50 7.15 206 1.32 - - 135 187 248 320 406 506 - - - - RSIR/CSIR
230/60 241 1.37 - - 157 219 294 384 491 618 - - - -
FFI 10HAK
50-60Hz
220-240/50 9.04 249 1.30 - - 153 218 300 398 509 634 - - - - RSIR/CSIR
230/60 302 1.42 - - 186 268 362 470 598 749 - - - -
FFI 10HAK 115-127/60 9.04 302 1.42 - - 187 268 362 470 598 749 - - - - RSIR/CSIR
FFI 12HBK
50-60Hz
220-240/50 11.14 319 1.25 1,316 2.61 209 285 381 496 631 787 965 1,164 1,386 1,631 RSIR/CSIR
230/60 349 1.18 1,553 2.28 221 308 419 554 714 901 1,116 1,361 1,637 1,946 CSIR
FFI 12HBK 115-127/60 11.14 349 1.20 1,553 2.54 218 304 414 552 718 913 1,140 1,400 1,694 2,024 RSIR/CSIR
FFU 130HAX 220-240/50 10.61 309 1.38 - - 201 178 368 475 604 761 - - - - CSIR
FFU 160HAX 220-240/50 12.92 388 1.46 - - 266 355 456 577 726 909 1,134 - - - CSIR
FFUS 80HAK
50-60Hz
220-240/50 6.76 201 1.37 - - 134 181 239 310 395 496 616 - - - RSIR/CSIR
230/60 236 1.47 - - 154 212 282 367 468 587 752 - - -
FFUS 80HAK 115-127/60 6.76 236 1.44 - - 156 213 283 369 472 594 738 - - - RSIR/CSIR
FFUS 100HAK
50-60Hz
220-240/50 7.95 248 1.43 - - 166 225 300 391 498 621 761 - - - RSIR/CSIR
230/60 295 1.52 - - 194 267 359 469 595 736 890 - - -
FFUS 100HAK 115-127/60 7.95 295 1.58 - - 194 266 356 464 591 738 906 - - - RSIR/CSIR

 

Rated Test Conditions:

Condensing Temperature 54.4°C
Liquid Temperature 32.2°C
Suction Temperature 32.2°C
Ambient Temperature 32.2°C

 

 

 

SERIE EM R290

Model Power Source [V/Hz] Displacement [cc/rev] Capacity / Evaporating Temperature - ASHRAE Motor
type
Check Point -23.3°C Check Point +7.2°C -30°C -25°C -20°C -15°C -10°c -5°C 0°C +5°C +10°C +15°C
CAP [W] COP [W/W] CAP [W] COP [W/W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W]
EMI 50UER
50-60Hz
220-240/50 3.00 127 1.28 - - 91 118 147 178 212 248 - - - - RSIR/CSIR
230/60 153 1.33 - - 103 138 181 231 290 355 - - - -
EMI 70UER
50-60Hz
220-240/50 4.10 177 1.18 - - 120 159 208 266 332 407 - - - - RSIR/CSIR
230/60 210 1.31 - - 142 190 248 317 396 485 - - - -
EMI 90UEX 220-240/50 5.00 229 1.28 - - 184 213 230 261 334 474 - - - - CSIR

 

Rated Test Conditions:

Condensing Temperature 54.4°C
Liquid Temperature 32.2°C
Suction Temperature 32.2°C
Ambient Temperature 32.2°C

 

 

 

 SERIE EMC R290 (High Efficiency)

Model Power Source [V/Hz] Displacement [cc/rev] Capacity / Evaporating Temperature - ASHRAE Motor Type
Check Point -23.3°C Check Point +7.2°C -30.0°C -25.0°C -20.0°C -15.0°C -10.0°c -5.0°C 0°C +5.0°C +10.0°C +15.0°C
CAP [W] COP [W/W] CAP [W] COP [W/W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W]
EMC3117U 220-240/50 3.97 197 1.79 - - 145 182 228 282 345 416 496 - - - RSCR
EMC3119U 220-240/50 4.53 229 1.83 - - 164 210 266 332 406 489 582 - - - RSCR
EMC3121U 220-240/50 5.54 271 1.88 - - 192 249 313 385 465 553 649 - - - RSCR
EMC3125U 220-240/50 6.09 305 1.88 - - 218 278 350 435 533 643 766 - - - RSCR
EMC3130U 220-240/50 6.92 349 1.84 - - 243 311 394 491 601 725 863 - - - RSCR
EMC3134U 220-240/50 7.95 417 1.85 - - 309 385 478 587 713 855 1014 - - - RSCR
EMC3140U 220-240/50 9.04 459 1.77 - - 337 427 536 661 805 966 1145 - - - RSCR
EMC3145U 220-240/50 11.14 559 1.75 - - 409 517 646 797 969 1164 1380 - - - RSCR

 

Rated Test Conditions:

Condensing Temperature 54.4°C
Liquid Temperature 32.2°C
Suction Temperature 32.2°C
Ambient Temperature 32.2°C

 

 

 

SERIE F R290

Model Power Source [V/Hz] Displacement [cc/rev] Capacity / Evaporating Temperature - ASHRAE Motor
type
Check Point -23.3°C Check Point +7.2°C -30°C -25°C -20°C -15°C -10°c -5°C 0°C +5°C +10°C +15°C
CAP [W] COP [W/W] CAP [W] COP [W/W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W]
FFU 130UAX
50-60Hz
220-240/50 6.76 319 1.49 - - 224 286 366 463 577 707 - - - - CSIR
230/60 399 1.55 - - 295 367 451 552 675 824 - - - -
FFU 160UAX 220-240/50 7.95 399 1.45 - - 297 375 464 567 688 830 - - - - CSIR

 

Rated Test Conditions:

Condensing Temperature 54.4°C
Liquid Temperature 32.2°C
Suction Temperature 32.2°C
Ambient Temperature 32.2°C

 

 

 

VEM INVERTER SERIES - R134a/R513A

Model Power Source [V/Hz] Displacement [cc/rev] Capacity / Evaporating Temperature - ASHRAE Frequency range [rps]
Check Point -23.3°C Check Point +7.2°C -30°C -25°C -20°C -15°C -10°c -5°C 0°C +5°C +10°C +15°C
CAP [W] COP [W/W] CAP [W] COP [W/W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W]
VEMY 6HH 220-240/53-150 5.72 97 1.65 - - 61 86 118 156 202 255 - - - - 25
230 1.62 - - 153 208 273 348 433 528 - - - - 75

 

Rated Test Conditions:

Condensing Temperature 54.4°C
Liquid Temperature 32.2°C
Suction Temperature 32.2°C
Ambient Temperature 32.2°C

 

 

 

INVERTER COMPRESSOR R290

Model Power Source [V/Hz] Displacement [cc/rev] Capacity / Evaporating Temperature - ASHRAE Frequency range [rps]
Check Point -23.3°C Check Point +7.2°C -30°C -25°C -20°C -15°C -10°c -5°C 0°C +5°C +10°C +15°C
CAP [W] COP [W/W] CAP [W] COP [W/W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W]
FMFT 406U 220-240/46-150 6.44 140 1.74 - - 99 129 165 207 256 313 378 - - - 25
510 1.81 - - 363 467 586 718 865 1,025 1,198 - - - 75
FMFT 411U 220-240/60-150 11.14 287 1.77 - - 211 266 329 401 485 582 676 - - - 25
861 1.75 - - 634 798 986 1,203 1,455 1,747 2,028 - - - 75
FMFT 413U 220-240/60-150 12.92 403 1.76 - - 287 369 467 585 727 896 1,094 - - - 30
998 1.74 - - 726 922 1,141 1,381 1,644 1,931 2,242 - - - 75
FMFT 415U 220-240/50-170 14.77 469 1.81 - - 333 420 518 632 765 920 1,101 - - - 25
1,251 1.66 - - 924 1,174 1,451 1,755 2,089 2,453 2,847 - - - 80

 

Rated Test Conditions:

Condensing Temperature 54.4°C
Liquid Temperature 32.2°C
Suction Temperature 32.2°C
Ambient Temperature 32.2°C

 

 

 

SERIE R600a

Model Power Source [V/Hz] Displacement [cc/rev] Capacity / Evaporating Temperature - ASHRAE Motor
type
Check Point -23.3°C Check Point +7.2°C -30°C -25°C -20°C -15°C -10°c -5°C 0°C +5°C +10°C +15°C
CAP [W] COP [W/W] CAP [W] COP [W/W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W] CAP [W]
EMT 23CLP 220-240/50 4.50 77 1.22 - - 53 70 90 114 143 - - - - - RSIR
EMI 40CNP
50-60Hz
220-240/50 6.36 100 1.14 - - 67 90 118 152 194 244 - - - - RSIR
230/60 119 1.16 - - 88 115 145 181 227 284 - - - -
EM2C 46CLT 220-240/50 7.96 137 1.73 - - 93 124 162 208 263 - - - - - RSCR
EMT 56CLP 220-240/50 9.04 157 1.33 - - 106 143 187 239 300 - - - - - RSIR/RSCR
EMYE 70CLP
50-60Hz
220-240/50 10.61 200 1.34 - - 128 171 250 285 350 - - - - - RSIR
230/60 238 1.39 - - 169 219 308 340 409 - - - - -
EGYS 110CLC 220-240/50 14.77 263 1.83 - - 187 241 307 387 486 - - - - - RSCR
                                   
EMT 45CDP 220-240/50 6.78 - - 397 2.71 - - - 152 192 239 296 361 - - RSIR
EMT 6144Y 220-240/50 9.04 - - 539 2.48 - - - 216 273 337 410 494 - - CSIR
EMT 6160Y 220-240/50 11.14 - - 654 2.27 - - - 262 329 408 498 600 - - CSIR

 

Rated Test Conditions:

Condensing Temperature 54.4°C
Liquid Temperature 32.2°C
Suction Temperature 32.2°C
Ambient Temperature 32.2°C